S7 300 for Siemens Processor Controller

6ES7317-2EK13-0AB0
SIMATIC S7-300 CPU 317-2 PN/DP, Central processing unit with 1 MB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface Ethernet PROFINET, with 2-port switch, Micro Memory Card required
Chat Now

Product Details

Product Description

6ES7317-2EK13-0AB0

SIMATIC S7-300 CPU 317-2 PN/DP, Central processing unit with 1 MB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface Ethernet PROFINET, with 2-port switch, Micro Memory Card required

Brand Name

Siemens

Model Number

6ES7317-2EK13-0AB0

Net Weight (kg)

0,519 Kg

Place of Origin

Germany

Lead Time

In Stock

Packaging Dimension

13,20 x 15,40 x 8,90

Delivery Time

2-3 days

Specifications

1st interface MPI/DP 12 Mbit/s


Detailed Images

General information

HW functional status : 01

Firmware version :V2.6

Engineering with

● Programming package STEP 7 V5.4 SP2

Supply voltage

Rated value (DC)

● 24 V DC : Yes

permissible range, lower limit (DC) :20.4 V

permissible range, upper limit (DC) :28.8 V

external protection for power supply lines

(recommendation) 2 A min.

Input current

Current consumption (rated value) :650 mA

Current consumption (in no-load operation), typ.: 100 mA

Inrush current, typ.: 2.5 A

I²t :1 A²·s

Power loss

Power loss, typ. :3.5 W

Memory

Work memory

● integrated 1 Mbyte; For program and data

● expandable No

● Size of retentive memory for retentive data

blocks :256 kbyte

Load memory

● Plug-in (MMC) :Yes

● Plug-in (MMC), max. :8 Mbyte

● Data management on MMC (after last

programming), min. :10 y

Backup

● present :Yes; Guaranteed by MMC (maintenance-free)

● without battery :Yes; Program and data

CPU processing times

for bit operations, typ. 0.05 µs

for word operations, typ. 0.2 µs

for fixed point arithmetic, typ. 0.2 µs

for floating point arithmetic, typ. 1 µs

CPU-blocks

Number of blocks (total) 2 048; (DBs, FCs, FBs); the maximum number of loadable blocks

can be reduced by the MMC used.

DB

● Number, max. 2 047; Number band: 1 to 2047

● Size, max. 64 kbyte

FB

● Number, max. 2 048; Number range: 0 to 2047

● Size, max. 64 kbyte

FC

● Number, max. 2 048; Number range: 0 to 2047

● Size, max. 64 kbyte

OB

● Size, max. 64 kbyte

● Number of free cycle OBs 1; OB 1

● Number of time alarm OBs 1; OB 10

● Number of delay alarm OBs 2; OB 20, 21

● Number of cyclic interrupt OBs 4; OB 32, 33, 34, 35

● Number of process alarm OBs 1; OB 40

● Number of DPV1 alarm OBs 3; OB 55, 56, 57

● Number of isochronous mode OBs 1; OB 61

● Number of startup OBs 1; OB 100

● Number of asynchronous error OBs 6; OB 80, 82, 83, 85, 86, 87

● Number of synchronous error OBs 2; OB 121, 122

Nesting depth

● per priority class 16

● additional within an error OB 4

Counters, timers and their retentivity

S7 counter

● Number 512

Retentivity

— adjustable Yes

— lower limit 0

— upper limit 511

— preset Z 0 to Z 7

Counting range

— adjustable Yes

— lower limit 0

— upper limit 999

IEC counter

● present Yes

● Type SFB

● Number Unlimited (limited only by RAM capacity)

S7 times

● Number 512

Retentivity

— adjustable Yes

— lower limit 0

— upper limit 511

— preset No retentivity

Time range

— lower limit 10 ms

— upper limit 9 990 s

IEC timer

● present Yes

● Type SFB

● Number Unlimited (limited only by RAM capacity)

Data areas and their retentivity

retentive data area in total All, max.: 256 KB

Flag

● Number, max. :4 096 byte

● Retentivity available Yes; From MB 0 to MB 4095

● Retentivity preset MB 0 to MB 15

● Number of clock memories 8; 1 memory byte

Data blocks

● Retentivity adjustable Yes; via non-retain property on DB

● Retentivity preset Yes

Local data

● per priority class, max. 1 024 byte

Address area

I/O address area

● Inputs 8 192 byte

● Outputs :8 192 byte of which distributed

— Inputs :8 192 byte

— Outputs 8 192 byte

Process image

● Inputs 2 048 byte

● Outputs 2 048 byte

● Inputs, adjustable 2 048 byte

● Outputs, adjustable 2 048 byte

● Inputs, default 256 byte

● Outputs, default 256 byte

Subprocess images

● Number of subprocess images, max. 1

Digital channels

● Inputs 65 536

— of which central 1 024

● Outputs 65 536

— of which central 1 024

Analog channels

● Inputs 4 096

— of which central 256

● Outputs 4 096

— of which central 256

Hardware configuration

Number of expansion units, max. 3

Number of DP masters

● integrated 1

● via CP 4

Number of operable FMs and CPs (recommended)

● FM 8

● CP, PtP 8

● CP, LAN 10

Time of day

Clock

● Hardware clock (real-time) Yes

● retentive and synchronizable Yes

● Backup time 6 wk; At 40 °C ambient temperature

● Deviation per day, max. 10 s

● Behavior of the clock following POWER-ON Clock continues running after POWER OFF

● Behavior of the clock following expiry of backup

period

Clock continues to run with the time at which the power failure

occurred

Operating hours counter

● Number 4

● Number/Number range 0 to 3

● Range of values 0 to 2^31 hours (when using SFC 101)

● Granularity 1 h

● retentive Yes; Must be restarted at each restart

PROFIBUS DP slave

● Transmission rate, max. 12 Mbit/s

● automatic baud rate search Yes; only with passive interface

● Address area, max. 32

● User data per address area, max. 32 byte

PROFINET IO Controller

● Transmission rate, max. 100 Mbit/s

Services

— PG/OP communication Yes

— Routing Yes

— S7 communication Yes; with loadable FBs, max. configurable connections: 16, max.

number of instances: 32

— Open IE communication Yes; Via TCP/IP, ISO on TCP, and UDP

— Number of connectable IO Devices, max. 128

— Send cycles 1 ms

— Updating time 1 to 512 ms (minimum value depends on communication share

set for PROFINET I/O, on the number of I/O devices, and on the

volume of configured user data)

Address area

— Inputs, max. 8 kbyte

— Outputs, max. 8 kbyte

— User data consistency, max. 254 byte

PROFINET CBA

● acyclic transmission Yes

● cyclic transmission Yes

Protocols

Open IE communication

● TCP/IP Yes; via integrated PROFINET interface and loadable FBs

— Number of connections, max. 8

— Data length for connection type 01H, max. 1 460 byte

— Data length for connection type 11H, max. 8 192 byte

● ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface and loadable FBs

— Number of connections, max. 8

— Data length, max. 8 192 byte

● UDP Yes; via integrated PROFINET interface and loadable FBs

— Number of connections, max. 8

— Data length, max. 1 472 byte

Web server

● supported Yes; only read function

● Number of HTTP clients 5

Communication functions

PG/OP communication Yes

Data record routing No

PROFINET CBA (at set setpoint communication load)

● Setpoint for the CPU communication load 50 %

● Number of remote interconnection partners 32

● Number of functions, master/slave 30

● Total of all master/slave connections 1 000

● Data length of all incoming connections

master/slave, max.

4 000 byte

● Data length of all outgoing connections

master/slave, max.

4 000 byte

● Number of device-internal and PROFIBUS

interconnections

500

● Data length of device-internal und PROFIBUS

interconnections, max.

4 000 byte

● Data length per connection, max. 1 400 byte

Remote interconnections with acyclic transmission

— Sampling frequency: Sampling time, min. 500 ms

— Number of incoming interconnections 100

— Number of outgoing interconnections 100

— Data length of all incoming

interconnections, max.

2 000 byte

— Data length of all outgoing

interconnections, max.

2 000 byte

— Data length per connection, max. 1 400 byte

Remote interconnections with cyclic transmission

— Transmission frequency: Transmission

interval, min.

10 ms

— Number of incoming interconnections 200

— Number of outgoing interconnections 200

— Data length of all incoming

interconnections, max.

2 000 byte

— Data length of all outgoing

interconnections, max.

2 000 byte

— Data length per connection, max. 450 byte

HMI variables via PROFINET (acyclic)

— Number of stations that can log on for HMI

variables (PN OPC/iMap)

3; 2x PN OPC/1x iMap

— HMI variable updating 500 ms

— Number of HMI variables 200

— Data length of all HMI variables, max. 2 000 byte

PROFIBUS proxy functionality

— supported Yes

— Number of linked PROFIBUS devices 16

— Data length per connection, max. 240 byte; Slave-dependent

Dimensions

Width :80 mm

Height :125 mm

Depth :130 mm

Weights

Weight, approx. 460 g


Our Main Market:

We main supply Brand new Siemens,PLC,Siemens plc,Siemens plc S7 200,Siemens S7 300, Siemens plc s7 400,S7 PLC, Siemens 200 plc, siemens plc 200,siemens 300 plc, siemens plc 300, siemens 400 plc, siemens plc 400,Simatic PLC, Simatic Siemens,s7 plc,siemens s7,simatic s7,s7-300,s7-400,s7-200,s7 1200,s7-1500

image005


Our team

image007


Packing & Delivery

image009


Our Company

image011

Inquiry

[[JS_PcIm]]