Simatic Et 200m Interface Module

6ES7155-6AU00-0CN0
SIMATIC ET 200SP, PROFINET interface module IM 155-6PN High Feature max. 64 I/O modules, 0.25 ms isochronous mode Multi-hotswap, incl. server module
Chat Now

Product Details

Product Description

6ES7155-6AU00-0CN0

SIMATIC ET 200SP, PROFINET interface module IM 155-6PN High Feature max. 64 I/O modules, 0.25 ms isochronous mode Multi-hotswap, incl. server module

Brand Name

Siemens

Model Number

6ES7155-6AU00-0CN0

Net Weight (kg)

0,2 Kg

Place of Origin

Germany

Lead Time

In Stock

Packaging Dimension

8,30 x 12,20 x 6,30

Delivery Time

2-3 days

Specifications

SIMATIC ET 200SP

image001(001)

We're not just sellers, we also have professional skills

General information

Product type designation IM 155-6 PN HF

Firmware version V3.3

Product function

● I&M data Yes; I&M0 to I&M4

● Module swapping during operation (hot swapping) Yes; Multi-hot swapping

Engineering with

● STEP 7 TIA Portal configurable/integrated as of

version

V13 SP1 Update 6

● STEP 7 configurable/integrated as of version V5.5 SP4 and higher

● PROFINET as of GSD version/GSD revision - / V2.3

Configuration control

via dataset Yes

Supply voltage

Rated value (DC) 24 V

permissible range, lower limit (DC) 19.2 V

permissible range, upper limit (DC) 28.8 V

Reverse polarity protection Yes

Mains buffering

● Mains/voltage failure stored energy time 5 ms

Input current

Current consumption, max. 700 mA

Inrush current, max. 4.5 A

I²t 0.09 A²·s

Power loss

Power loss, typ. 2.4 W

Address area

Address space per module

● Address space per module, max. 288 byte; For input and output data respectively

Address space per station

● Address space per station, max. 1 440 byte; Dependent on configuration

Hardware configuration Rack

● Modules per rack, max. 64; + 16 ET 200AL modules

Submodules

● Number of submodules per station, max. 256

Interfaces

Number of PROFINET interfaces 1; 2 ports (switch)

1. Interface

Interface types

● Number of ports 2

● integrated switch Yes

● BusAdapter (PROFINET) Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x

SCRJ (from FS03, V2.2), BA SCRJ / RJ45 (from FS03, V3.1), BA

SCRJ / FC (from FS03, V3.1), BA 2x LC (from FS03, V3.3), BA

LC / RJ45 (from FS03, V3.3), BA LC / FC (from FS03, V3.3)

Protocols

● PROFINET IO Device Yes

● Open IE communication Yes

● Media redundancy Yes; PROFINET MRP

Interface types

RJ 45 (Ethernet)

● Transmission procedure PROFINET with 100 Mbit/s full duplex (100BASE-TX)

● 10 Mbps No

● 100 Mbps Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX)

● Autonegotiation Yes

● Autocrossing Yes

Protocols

PROFINET IO Device

Services

— Isochronous mode Yes; Bus cycle time: min. 250 µs

— Open IE communication Yes

— IRT Yes; 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with

high performance: 250 µs to 4 ms in 125 µs frame

— PROFIenergy Yes

— Prioritized startup Yes

— Shared device Yes

— Number of IO Controllers with shared

device, max.

4

Redundancy mode

● MRP Yes

● MRPD No

● PROFINET system redundancy (S2) Yes; NAP S2

Open IE communication

● TCP/IP Yes

● SNMP Yes

● LLDP Yes

Isochronous mode

Isochronous operation (application synchronized up

to terminal)Yes

Equidistance Yes

shortest clock pulse 250 µs max. cycle 4 ms

Bus cycle time (TDP), min. 250 µs Jitter, max. 1 µs

Interrupts/diagnostics/status information

Status indicator Yes

Alarms Yes

Diagnostics function Yes

Diagnostics indication LED

● RUN LED Yes; Green LED

● ERROR LED Yes; Red LED

● MAINT LED Yes; yellow LED

● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED

● Connection to network LINK (green) Yes; 2x green link LEDs on BusAdapter

Connection method

ET-Connection

● via BU/BA Send Yes; + 16 ET 200AL modules

Dimensions

Width 50 mm

Height 117 mm

Depth 74 mm

Weights

Weight, approx. 147 g; without BusAdapter

image009(001)

Our Factory

image011(001)


Packing & Delivery

image013(001)


Our Company

image015(2)

Inquiry